15kv ACSR conductor hdtrxlpe insulated Tree wire Messenger Supported Spacer Cable
15kv ACSR conductor hdtrxlpe insulated Tree wire Messenger Supported Spacer Cable

15kv ACSR conductor hdtrxlpe insulated Tree wire Messenger Supported Spacer Cable

TREE wire Spacer Cable

Tree Wire - Used for spans where trees crowd the right-of-way, such as in wooded residential areas, when a minimum of interference with the environment is desired. Covering minimizes power outages due to conductor contact with tree limbs, reducing the need for frequent or severe trimming.

Implementation Standards
  • ASTM B230
  • ASTM B232
  • ASTM B498
  • ASTM B500
  • ICEA S-121-733
Contact Us

Product Introduction

Product Introduction: Covered Aerial Conductor

Construction

  1. Conductor: Concentrically stranded ACSR
  2. Inner Layer: Low-Density Track-Resistant Crosslinked Polyethylene (HDTRXLPE)
  3. Outer Layer: High-Density Track-Resistant Crosslinked Polyethylene (HDTRXLPE)

Applications and Features

This product is used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. It is installed the same as bare conductors; however, the covering is effective in preventing direct shorts and instantaneous flashovers should tree limbs or other objects contact conductors in close proximity.

Key applications include:
- Tree Wire: Used for spans where trees crowd the right-of-way, such as in wooded residential areas, when minimal interference with the environment is desired. The covering minimizes power outages due to conductor contact with tree limbs, reducing the need for frequent or severe trimming.
- Covered Aerial MV Cable: Installed with other Covered Aerial MV cables and a supporting messenger through a series of space-maintaining devices (spacers). The resulting close-proximity configuration minimizes the amount of space and hardware required for line installation, particularly useful in congested areas.

Temperature Rating: The covering is rated for 90°C normal operation and 130°C emergency operation. Unless adequate knowledge of the thermal characteristics of the environment is known, the permissible conductor temperature should be reduced by 10°C or in accordance with available data.

Specifications

The product complies with the following standards:
- ASTM B230: Aluminum, 1350-H19 Wire for Electrical Purposes
- ASTM B232: Concentric-Lay-Stranded, Aluminum Conductors, Coated Steel Reinforced (ACSR)
- ASTM B498: Zinc-Coated (Galvanized) Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR)
- ASTM B500: Metallic Coated Stranded Steel Core for use in overhead Electrical Conductors
- ICEA S-121-733: Tree Wire and Messenger Supported Spacer Cable

Technical Specifications

电缆规格参数表
Cond. Size
AWG/kcmil
Cond. Strands
#
Diameter Over Conductor
inch
Conductor Shield Thickness
mil
Inner Layer Thickness
mil
Outer Layer Thickness
mil
Approx. OD
inch
Approx. Weight
lb/1000Ft
Rated Strength
lb
46/10.2501575750.5551251767
26/10.3161575750.6462022708
1/06/10.3981575750.7282784161
2/06/10.4471575750.7773305045
3/06/10.5021575750.8323936289
4/06/10.5631575750.8934717933
266.818/10.6091575750.9394746536
266.826/70.6421575750.97255310735
336.418/10.6841575751.0145708246
336.426/70.7201575751.05066913395
336.430/70.7411575751.07193516435
397.518/10.7431575751.0736539443
397.524/70.7721575751.10270713870
397.526/70.7831575751.11377015485
47724/70.8461575751.17682416340
47726/70.8581575751.18889918525
47730/70.8771575751.213103722610
556.518/10.8792075751.21987413015
556.524/70.9142075751.25494918810
556.526/70.9272075751.267127421470
63618/10.9402075751.280120014915
63626/70.9902075751.330137323940

Application Fields

overhead

Packaging & Shipping

All cables will be packaged in different materials based on their outer diameter and net weight, and can be customized according to requirements

Shipping and Packaging